Dell PowerVault MD38XX Storage Series

TieDot Technologies Provides New, Used and Refurbished Dell PowerVault MD3800i and MD3820i Series Storage in India – Bangalore for price and availability Call: +91-9035020041 | +91-9036000187 Email: sales@tiedottechnologies.com

Technical Specifications

Physical disksUp to twelve 3.5 inch or twenty-four 2.5 inch SAS, nearline SAS physical disks, or SAS SSDs
RAID controller modulesTwo hot-swappable modules with temperature sensors4GB or 8GB of cache per controller
   
   
  Provides host-to-controller iSCSI 10 Gbps Ethernet connection
Dell PowerVault MD1200 and MD1220 expansion enclosuresEach expansion enclosure holds Up to twelve 3.5 inch or twenty-four 2.5 inch SAS, nearline SAS physical disks, or SAS SSDsRedundant path connectivity provides redundant data paths to each hard driveNOTE: Support for 192 physical disks is a premium feature and requires activation.
 SAS connectorsTwo SAS IN ports to connect hostsOne SAS OUT port for expansion to additional PowerVault MD1200 or MD1220 expansion enclosureNOTE: SAS connectors are SFF-8088 compliant.
 Serial connector (debug port)One 6-pin mini-DIN connectorNOTE: For technical support use only.
 SAS connectorsTwo SAS OUT ports for expansion to additional PowerVault MD1200 or MD1220 expansion enclosuresNOTE: SAS connectors are SFF-8088 compliant.NOTE: It is recommended that you use one port.
 iSCSI connectorsTwo 10 Gbps iSCSI IN connectors to connect hosts
   
 Serial connector (debug port)One mini-USB portNOTE: For technical support use only.
 Management Ethernet connectorOne 100/1000 Mbps Ethernet connection for out-of-band management of the enclosure (MGMT)
AC power supply (per power supply) 
 Wattage600 W
 Heat dissipation (maximum)NOTE: Heat dissipation is calculated using the power supply wattage rating. The heat dissipation values are for the entire system which includes chassis and two controllers.100 W
 VoltageNOTE: This system is also designed to be connected to IT power systems with a phase to phase voltage not exceeding 230 V.100–220 V AC, (8.6 A-4.3 A)
Battery6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery
  
NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets.
Temperature 
 OperatingContinuous operation: 10 °C to 35 °C (50 °F to 95 °F) at 20% to 80% relative humidity (RH), with 26 °C maximum dew point. De-rate maximum allowable dry bulb temperature at 1 °C/300 m (1 °F per 550 ft) above 900 m (2952.75 ft).NOTE: For information on supported expanded operating temperature range and configurations, see the Owner’s Manual at dell.com/powervaultmanuals.
 Storage–40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour
Relative humidity 
 Operating10% to 80% (noncondensing) with maximum humidity gradation of 10% per hour
 Storage5% to 95% at a maximum wet bulb temperature of 33 °C (91 °F)
Maximum vibration 
 Operating0.26 G rms at 5 Hz to 350 Hz in operational orientation
 Storage1.88 G rms at 10 Hz to 500 Hz for 15 minutes (all six sides tested)
Maximum shock 
 OperatingOne shock pulse in the positive z axis of the system at 31 G for 2.6 ms in the operational orientation
 StorageSix consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) at 71 G for up to 2 ms
Altitude 
 OperatingMaximum 3000 m (9842.5 ft)NOTE: For altitudes above 2950 ft, the maximum operating temperature is derated 1.8 ºF/1000 ft.
 StorageMaximum 12192 m ( 40,000 ft)
Airborne contaminant level
 ClassG1 as defined by ISA-S71.04-1985
 
 
 
 
 
NOTE: This section defines the limits to help avoid IT equipment damage and/or failure from particulates and gaseous contamination. If it is determined that levels of particulates or gaseous pollution are beyond the limits specified below and are the reason for the damage and/or failures to your equipment, it may be necessary for you to re-mediate the environmental conditions that are causing the damage and/or failures. Re-mediation of environmental conditions will be the responsibility of the customer.
 Air FiltrationNOTE: Applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor.Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit.NOTE: Air entering the data center must have MERV11 or MERV13 filtration.
 Conductive DustNOTE: Applies to data center and non-data center environments.Air must be free of conductive dust, zinc whiskers, or other conductive particles.
 Corrosive DustNOTE: Applies to data center and non-data center environments.Air must be free of corrosive dust.Residual dust present in the air must have a deliquescent point less than 60% relative humidity.
Gaseous Contamination
NOTE: Maximum corrosive contaminant levels measured at ≤50% relative humidity.
 Copper Coupon Corrosion Rate<300 Å/month per Class G1 as defined by ANSI/ISA71.04-1985.
 Silver Coupon Corrosion Rate<200 Å/month as defined by AHSRAE TC9.9